JCAHO Unannounced Survey

This link will take you to a part of the Joint Commission Web site that provides more information about Unannounced Surveys.

PM - Professional Services

Preventative Maintenance Services for Piped Medical Gas Systems

Services include:
Complete Piped Medical Gas Inspection

Alarm Services:

  • Normal operating bulb replacement
  • Alarm panel screw replacement
  • General tightening of faceplates
  • Inspection of Alarm Panel Operations


Zone Valve Services:

  • Ultrasonic leak detection
  • General cleaning of valve box
  • Gas content labeling
  • Rooms controled labeling posted


Terminal Services:

  • Terminal screw replacement
  • Front body O-ring replacement (if available)
  • General tightening of faceplates
  • External cleaning
  • Vacuum enzyme cleaning solution injected

Documentation Includes:

  • Alarm Inspection
  • Zone valve inspection
  • Terminal Inspection
  • Deficiencies and Recommendations
    Update Documentation of Current Code Compliance

Optional Services:

  • Low alarm activation point verification*
  • High alarm activation point verification
  • In-service training where needed
  • Valve and terminal rebuild kits (if available)
  • Back body O-ring replacement where needed

    *Requires gas shut-down


Performing Preventative Maintenance Ensures Compliance
  • Joint Commission on Accreditation of Healthcare Organizations (JCAHO)Environment of Care
  • National Fire Protection Association (NFPA) 99
  • Uniform Plumbing Code (UPC) Specifications
  • Compressed Gas Association (CGA) Commodity Specifications, E-10 Maintenance of Medical Gas and Vacuum Systems in Healthcare Facilities
  • American Hospital Association (AHA) Hospital Engineering Handbook
  • United States Pharmacopeia
  • American National Standards Institute (ANSI)

 

Back To Top

 

Medical Gas Verification Service


Services to Ensure Compliance with NFPA 99, and CGA Codes & Standards for all New Installations

 

Certification Services include:

  • Immediate notification of item(s) that may delay
    or prevent verification.
  • Impartial third-party documentation as required
    by NFPA 99
  • Verification of installer performance testing
  • Recommendations of corrective action(s)

Documentation Includes:
Documentation of testing for all patient terminals
to include:

- Cross-connection testing
- Proper operation
- Pressure and flow
- Labeling
- Leakage

Documentation of testing for alarms, valves,
gauges, and piping to include:

- Alarm activation points
- Alarm area of surveillance labeling
- Alarm emergency instructions labeling
- Proper alarm location
- Gauge accuracy
- Zone valve inspection for area of control
labeling, location, and leakage per NFPA99

Documentation of testing for solid and gaseous
contamination:

- Solid particulate sampling
- Gaseous contaminant screening in
accordance with NFPA 99
- Gas concentrations

Certification Services Ensure Compliance
  • National Fire Protection Association (NFPA) 99, 50, per latest edition
  • Joint Commission on Accreditation of Healthcare Organizations (JCAHO) Environment of Care
  • Compressed Gas Association (CGA) Commodity Specifications, E-10 Maintenance of Medical Gas and Vacuum Systems in Healthcare Facilities
  • American Hospital Association (AHA) Hospital Engineering Handbook
  • ASME Boiler and Pressure Vessel Code
  • Department of Health and Human Services (DHHS), “Guidelines for Design and Construction of Hospitals and Healthcare Facilities”
  • United States Pharmacopeia
  • American National Standards Institute (ANSI)

Optional Design & Management Services:

  • Comprehensive specification review to clarify and
    define all aspects of the installation, testing
    and verification of the system(s).
  • Plan review services:
    - Layout
    - Sizing of equipment to be installed
    - Configuration
    - Source supply system design
    - Future maintenance considerations
  • Inspection of contractors to ensure proper
    installation
  • Supplies and equipment acquisition assistance

Back To Top


Piped Medical Gas Inspection

Oxygen, Medical Air, Vacuum, Evacuation, Nitrous Oxide, Nitrogen, CO2



Compliance Eval & Performance Testing

Gas Warning Systems


Master, Local, and Area alarm Compliance Testing

  • Audible and visual signals
  • Proper location and condition
  • Labeling verification to include:
    - Area of surveillance
    - Emergency Instructions
    - Gas Content


Gas Shutoff Valves Source, Main, Zone valve compliance verification

  • Proper location and condition
  • Leakage
  • Labeling verification to include
    - Area of Control
    - Emergency Instructions
    - Gas Content


Terminals

  • Leakage
  • Pressure and Flow
  • Proper operation and condition
  • Labling verification

 

Source Equipment Evaluation

  • Source efficiency and output evaluation
  • Intake/exhaust verification and inspection
  • Configuration evaluation including all applicable components for risk assessment


Piping Purity Compliance Testing

Solid and gaseous contamination evaluation

  • Solid particulate
  • Temperature and dew point
  • Odor
  • Gas concentration
  • Carbon Monoxide
  • Nitrous Oxide
  • Carbon Dioxide
  • Condensed Hydrocarbons
  • Gaseous Hydrocarbons
  • Halogenated Hydrocarbons

 

Reasons for Certification Services
  • National Fire Protection Association (NFPA) 99, 50, 70, 101
  • Joint Commission on Accreditation of Healthcare Organizations (JCAHO) Environment of Care
  • Uniform Plumbing Code (UPC) Specifications
  • Compressed Gas Association (CGA) Commodity Spec’s, E-10 Maintenance of Medical Gas and Vacuum Systems in Healthcare Facilities
  • American Hospital Association (AHA) Hospital Engineering Handbook
  • ASME Boiler and Pressure Vessel Code
  • Department of Health and Human Services (DHHS), “Guidelines for Design and Construction of Hospitals and Healthcare Facilities”
  • United States Pharmacopeia
  • American National Standards Institute (ANSI)

 

Back To Top


Piped Medical Gas Equipment

Pipeline, Architectural, & Source Equipment for Medical Gas Projects

Vacuum Pumps & Medical Air Compressors

  • Duplex, Triplex and Quadraplex Systems
  • Oil-Free, Oil-Less, Screw type
  • Manifold Systems (MA, N2O, N2, O2, CO2)

Accessories:

  • Pigtails, Stand
  • Emergency Oxygen Connection
  • Pressure Relief Valves
  • Filter Sets (Single & Duplex)
  • Intake Filters
  • Exhaust Filter / Muffler
  • Skids, Vibration Mounting

Drying Systems

  • Refrigerated, Desiccant
  • Purifiers
  • Filters

 

Alarms

  • Master, Area and Local
    - Analog and Digital
    - Computer Integration Link Available
    - Retrofit
  • CO2 and Dew Point Monitors
    (Sold in Packages or Independently)

Valves

  • Check
  • Zone Valve Boxes
  • Gauges
  • 1/4 Turn Ball
  • (1/2” to 5” Clean for O2 Service)

Terminals

  • DISS
  • Quick-connect
  • Terminal Rebuild Kits

Secondary Products

  • Adapters, couplers and Fittings (All Types)
  • Custom Assembled or Blank
  • Flow Meters
    - Oxygen
    - Medical Air
CHT Equipment and Projects
The equipment and systems listed above include those most commonly requested; additional equipment and systems
are available, and nearly every equipment order or installation project can be performed as a turn-key operation.

All Projects are NFPA 99, ASSE Series 6000, and CGA compliant

Back To Top


CHT Construction Management Services

TURNKEY Package - Your Option


Medical Gas Turnkey construction :

  • Turnkey Projects include:
    - Bulk Site Prep
    - Concrete Pad Pours
    - Fencing
    - Electrical Wiring
    - Alarm Wiring
    - Copper Piping Installation
  • Turnkey Systems Can Include:*
    - Vacuum Pumps and Medical Air Compressors
    - Dryer Systems
    - Manifolds
    - Alarm Systems
    - Valves
    - Terminals
    - Booms
  • Blueprint Reviews

Optional Design & Management Services:

  • Comprehensive specification review to clarify and
    define all aspects of the installation, testing
    and verification of the system(s).
  • Plan review services:
    - Layout
    - Sizing of equipment to be installed
    - Configuration
    - Source supply system design
    - Future maintenance considerations
  • Inspection of contractors to ensure proper
    installation
  • Supplies and equipment acquisition assistance

Other Services Include:

  • Alarm Services:
  • Master Alarm
    - Evaluations
    - Upgrades
    - Replacements
  • Area Alarm
    - Retrofits
    - Replacements

Hyperbaric Services

  • Facility Evaluation
    - Bulk tank
    - Vaporizers
    - Existing Pipeline Sizing
  • Facility Upgrades to accomodate installation
    - O2 tank/vaporizer/line upgrade
  • Complete Hyperbaric Installation Project Management


A Complete Package You Can Trust
• All CHT contractors are specialists in Medical Gas Service and
are Licensed or Credentialed in their respective field.
• CHT Construction Management Services offers Equipment,
Verification, and Installation Services, or any combination for
a turnkey package that fits your need
• The projects, equipment and services listed include those
most commonly requested; additional equipment and
systems are available.

ALL PROJECTS ARE NFPA 99,
ASSE Series 6000, and CGA Compliant

*These services can include Equipment, Installation, and Verification, or any combination thereof

Back To Top

 

Piped Medical Gas Dist. & Control Diagram

Services to Evaluate and Document the Distribution
and Control of the Piped Medical Gas Utility Systems


Diagrams and Documentation Include:

  • Color-coded 8 1⁄2” X 11” (landscape) CAD diagrams
    which utilize cross-hatching of the individual zones
    to denote the area of control for each zone valve
    and each medical gas.

  • Temporary labels and zone codes are applied to
    zone valves . The facility may elect to label zone
    valve boxes with an alternate coding system.
  • Written reports tabbed by section are provided to
    the facility, defining the location and distribution of
    all zone valves and patient terminals.

  • Diagrams are designed to assist in achieving
    compliance with JCAHO Environment of Care and
    NFPA standards.

  • Documentation indicates the distribution of each
    piped medical gas utility system, which allows for a
    safe and timely emergency shutdown.

Emergency Zone Valve Labeling:

  • Permanent placards replace temporary
    labels at each valve location.
  • Placards include area of control, type of medical
    gas, valve code identification, and system
    information.

Optional Services:

  • Placards designed with custom font, type and color.
  • Alarm placards with labeling to include area of surveillance, emergency instructions and gas content.
  • Additional drawings posted at each zone valve box.


Distribution and Control Diagrams Ensure
Compliance


  • Joint Commission on Accreditation of Healthcare
    Organizations (JCAHO) Environment of Care
  • National Fire Protection Association (NFPA) 99
  • Accurate distribution and control diagrams clearly
    outline shutoff valve control information and improves
    staff reaction time in an emergency

Click HERE to Download the ENTIRE CHx Professional Services Brochure PDF

 